SM-909-N-21 Models

Features:

  • Sealless/Leakproof Design
  • Whisper Quiet (less than 30 dbs.)
  • Low Capacity/High Head Performance
  • Rated for temperatures to 140 degree F and line pressures to 30 PSI
  • Requires only 98 watts of power
  • Dry run cutout provided on pumps

Material of Wetted Parts:

  • Noryl HousingUL Logo.gif (2742 bytes)
  • 316 Stainless Steel Rotor and Separating Wall
  • Noryl Impeller
  • Ceramic Bearing Ball
  • Carbon Graphite Bearing Cap
  • EPDM O-Ring

 

Technical Info:

Model

Volts

Cycle

Phase

Watts

Amps

Maximum. Pressure

Maximum Temperature

Weight (lbs.)

SM-909-N-21

115

60

1

98

0.95

50 PSI

140F

4.2

SM-909-N-21

230

60

1

98

0.47

50 PSI

140F

4.2

SM-959-N-21 230 50 1 88 0.38 50 PSI 140F 4.2


Performance Curve:

 


Dimension Drawing:

SM-909-NH Dimension Drawing.gif (10067 bytes)

 

Ordering Information:

Standard pump configuration includes noryl angled housing, external capacitor, and two 6 inch pigtails for hard wiring.

Housing Connection Codes:
NH - 1" Male Hosebarb

Options Available:

  • 6 ft. line cord with plug
  • Mounting Bracket
  • 115V or 230V Motors


Copyright © 2005 Laing Thermotech, Inc.