SM-909-B-14 Models

Features:

  • Sealless/Leakproof Design
  • Low Capacity/High Head Performance
  • Rated for temperatures to 230 degree F and line pressures to 150 PSI
  • Requires only 65 watts of power
  • Dry run cutout provided on pumps for hot water recirculation

Material of Wetted Parts:

  • Brass HousingUL Logo.gif (2742 bytes)
  • 316 Stainless Steel Rotor and Separating Wall
  • Noryl Impeller
  • Ceramic Bearing Ball
  • Carbon Graphite Bearing Cap
  • EPDM O-Ring

 

Technical Data:

Model

Volts

Cycle

Ph.

Watts

Amps

Maximum. Pressure

Maximum Temperature

Weight (lbs.)

SM-909-B-14

115

60

1

65

0.58

150 PSI

230F

6.5 BS
8.0 BF

SM-909-B-14

230

60

1

65

0.29

150 PSI

230F

6.5 BS
8.0 BF

SM-959-B-14

230

50

1

55

0.25

150 PSI

230F

6.5 BS
8.0 BF


Performance Curve:

SM-909-B-14 Curve.gif (10363 bytes)

 


Dimension Drawings:

Ordering Information:

Standard pump configuration includes brass inline sweat or flanged housing, external capacitor, and two 6 inch pigtails for hard wiring.

Housing Connection Codes:
BS 1/2" - 1/2" Bronze Sweat Housing
BS 3/4" - 3/4" Bronze Sweat Housing
BF - Bronze Flanged Housing

Options Available:

  • 6 ft. line cord with plug (115V models Only)
  • 230V, 60Hz, 50Hz, and 24VAC motors
  • Built-in 130 degree F internal thermostat

 

Copyright © 2005 Laing Thermotech, Inc.